※ high-grade aluminum 2U black drawing panel, nice; ※ 30 district fire alarm intelligent interface, automatic activation; ※ Programmable setting N ± 1 or N ± 4 Neighbor level (zone) Automatic alarm trigger; ※ N ± 1 or N ± 4 with 8-bit address selection switch; ※ 30 green LED visual display corresponding to the district; ※ 30 alarm activation signal input; ※ 3 groups (1 ~ 10, 11 ~ 20,21 ~ 30) a total of 30 alarm activation signal output; ※ 25-pin computer interface for alarm signal input / output; ※ has two short circuit to activate the output port; ※ has a high and low alarm signal selection switch; ※ through the panel manually press the button to trigger the region alarm;
※ Equipment Model: HS19A; ※ Activate the output port ALARM: (high level (+ 5V ~ + 24V) or low (0V)); ※ can control the number of channels: thirty road (activated by the alarm signal) 'CH1 ~ CH30'; ※ Alarm active level selection: high (+ 5V ~ +24 V) or low (0V), by the INPUT LEVEL setting switch to select 'HIGH' / 'LOW'; ※ alarm activation input: a group of 'ALARM (1 ~ 30)'; ※ alarm activation output: three groups 'OUT (1 ~ 10), OUT (11 ~ 20), OUT (21 ~ 30)'; ※ Activate the number of adjacent areas: ± 1, ± 2, ± 3, ± 4; ※ Power cord: (3 × 0.75 mm2) × 1.5M (standard); ※ Power: AC 220V ± 10% 50-60Hz; ※ power consumption: 15 ~ 20W; ※ Machine size: 89 (H) × 483 (W) × 350 (D) mm; ※ Net weight: 6.42kg;